Contents |
OFNR Riser (PVC)
Optical Fiber Nonconductive Riser (OFNR) cable is intended for vertical runs between floors or non-plenum applications.
| Mode | Singlemode |
|---|---|
| Core/Clad | 8.3/125 |
| N/A | .14 |
| Type. Atten. (dB/km) | 0.5/0.4 |
| Max. Atten. (dB/km) | 1.0/0.75 |
| Bandwidth (Mhz*km) Corning# | SMF28e |
| Diameter (mm) | 5.3 |
| Pull Load (N) Install/Operate |
1000/300 |
| Bend Radius (cm) Install/Operate |
89.0/6.0 |
| Buffer Size (um) | 900 |
| Storage Temp. (°C) | -40 / +85 |
| Operating Temp. (°C) | -20 / +85 |
OFNP Plenum
Optical Fiber Nonconductive Plenum (OFNP) cable is intended for horizontal runs within ceilings, air ducts, and where required by local fire code.
| Mode | Singlemode |
|---|---|
| Core/Clad | 8.3/125 |
| N/A | .14 |
| Type. Atten. (dB/km) | 0.5/0.4 |
| Max. Atten. (dB/km) | 1.0/0.75 |
| Bandwidth (Mhz*km) Corning# | SMF28e |
| Diameter (mm) | 5.3 |
| Pull Load (N) Install/Operate |
1000/300 |
| Bend Radius (cm) Install/Operate |
9.0/6.0 |
| Buffer Size (um) | 900 |
| Storage Temp. (°C) | -40 / +85 |
| Operating Temp. (°C) | -20 / +85 |
Indoor/Outdoor Riser
Indoor/Outdoor cable can withstand the strains of outdoor use but also meets the flammability requirements of indoor cables. Like OFNR riser cable, when using indoor/outdoor riser cable indoors, it is intended for vertical runs between floors or non-plenum applications.
| Mode | Singlemode |
|---|---|
| Core/Clad | 8.3/125 |
| N/A | .14 |
| Type. Atten. (dB/km) | 0.5/0.4 |
| Max. Atten. (dB/km) | 1.0/0.75 |
| Bandwidth (Mhz*km) Corning# | SMF28e |
| Diameter (mm) | 5.3 |
| Pull Load (N) Install/Operate |
1000/300 |
| Bend Radius (cm) Install/Operate |
9.0/6.0 |
| Buffer Size (um) | 900 |
| Storage Temp. (°C) | -40 / +85 |
| Operating Temp. (°C) | -20 / +85 |
Indoor/Outdoor Plenum
Indoor/Outdoor cable can withstand the strains of outdoor use but also meets the flammability requirements of indoor cables. Like OFNP plenum cable, when using indoor/outdoor plenum cable indoors, it is intended for horizontal runs within ceilings, air ducts, and where required by local fire code.
| Mode | Singlemode |
|---|---|
| Core/Clad | 8.3/125 |
| N/A | .14 |
| Type. Atten. (dB/km) | 0.5/0.4 |
| Max. Atten. (dB/km) | 1.0/0.75 |
| Bandwidth (Mhz*km) Corning# | SMF28e |
| Diameter (mm) | 5.3 |
| Pull Load (N) Install/Operate |
1000/300 |
| Bend Radius (cm) Install/Operate |
9.0/6.0 |
| Buffer Size (um) | 900 |
| Storage Temp. (°C) | -40 / +85 |
| Operating Temp. (°C) | -20 / +85 |
Aerial (Self-supporting)
Designed to be strung from poles outdoors, this cable has an internal stress member that protects the fibers from strain.
| Mode | Singlemode |
|---|---|
| Core/Clad | 8.3/125 |
| Attenuation (dB/km) | 0.5/0.5 |
| Diameter (mm) | 8.0 |
| Buffer Size (um) | 900 |
| Storage Temp. (°C) | -70 / +85 |
| Operating Temp. (°C) | -55 / +85 |
Direct Burial
Direct burial cable is intended for use in ducts, buried directly underground, or lashed aerial applications. It features an armor layer inside the jacket to help prevent damage.
| Mode | Singlemode |
|---|---|
| Core/Clad | 8.3/125 |
| Max. Atten. (dB/km) | 0.4/0.3 |
| Diameter (mm) | 13.46 |
| Max. Installation Load (N) | 2700 |
| Bend Radius (cm) Short Term/Long Term |
26.9/20.2 |
| Storage Temp. (°C) | -50 / +80 |
| Operating Temp. (°C) | -40 / +70 |