Call 1-800-525-3303

Contents

OFNR Riser (PVC)

Optical Fiber Nonconductive Riser (OFNR) cable is intended for vertical runs between floors or non-plenum applications.

Mode Singlemode
Core/Clad 8.3/125
N/A .14
Type. Atten. (dB/km) 0.5/0.4
Max. Atten. (dB/km) 1.0/0.75
Bandwidth (Mhz*km) Corning# SMF28e
Diameter (mm) 5.3
Pull Load (N)
Install/Operate
1000/300
Bend Radius (cm)
Install/Operate
89.0/6.0
Buffer Size (um) 900
Storage Temp. (°C) -40 / +85
Operating Temp. (°C) -20 / +85

Top

OFNP Plenum

Optical Fiber Nonconductive Plenum (OFNP) cable is intended for horizontal runs within ceilings, air ducts, and where required by local fire code.

Mode Singlemode
Core/Clad 8.3/125
N/A .14
Type. Atten. (dB/km) 0.5/0.4
Max. Atten. (dB/km) 1.0/0.75
Bandwidth (Mhz*km) Corning# SMF28e
Diameter (mm) 5.3
Pull Load (N)
Install/Operate
1000/300
Bend Radius (cm)
Install/Operate
9.0/6.0
Buffer Size (um) 900
Storage Temp. (°C) -40 / +85
Operating Temp. (°C) -20 / +85

Top

 

Indoor/Outdoor Riser

Indoor/Outdoor cable can withstand the strains of outdoor use but also meets the flammability requirements of indoor cables. Like OFNR riser cable, when using indoor/outdoor riser cable indoors, it is intended for vertical runs between floors or non-plenum applications.

Mode Singlemode
Core/Clad 8.3/125
N/A .14
Type. Atten. (dB/km) 0.5/0.4
Max. Atten. (dB/km) 1.0/0.75
Bandwidth (Mhz*km) Corning# SMF28e
Diameter (mm) 5.3
Pull Load (N)
Install/Operate
1000/300
Bend Radius (cm)
Install/Operate
9.0/6.0
Buffer Size (um) 900
Storage Temp. (°C) -40 / +85
Operating Temp. (°C) -20 / +85

Top

Indoor/Outdoor Plenum

Indoor/Outdoor cable can withstand the strains of outdoor use but also meets the flammability requirements of indoor cables. Like OFNP plenum cable, when using indoor/outdoor plenum cable indoors, it is intended for horizontal runs within ceilings, air ducts, and where required by local fire code.

Mode Singlemode
Core/Clad 8.3/125
N/A .14
Type. Atten. (dB/km) 0.5/0.4
Max. Atten. (dB/km) 1.0/0.75
Bandwidth (Mhz*km) Corning# SMF28e
Diameter (mm) 5.3
Pull Load (N)
Install/Operate
1000/300
Bend Radius (cm)
Install/Operate
9.0/6.0
Buffer Size (um) 900
Storage Temp. (°C) -40 / +85
Operating Temp. (°C) -20 / +85

Top

 

Aerial (Self-supporting)

Designed to be strung from poles outdoors, this cable has an internal stress member that protects the fibers from strain.

Mode Singlemode
Core/Clad 8.3/125
Attenuation (dB/km) 0.5/0.5
Diameter (mm) 8.0
Buffer Size (um) 900
Storage Temp. (°C) -70 / +85
Operating Temp. (°C) -55 / +85

Top

Direct Burial

Direct burial cable is intended for use in ducts, buried directly underground, or lashed aerial applications. It features an armor layer inside the jacket to help prevent damage.

Mode Singlemode
Core/Clad 8.3/125
Max. Atten. (dB/km) 0.4/0.3
Diameter (mm) 13.46
Max. Installation Load (N) 2700
Bend Radius (cm)
Short Term/Long Term
26.9/20.2
Storage Temp. (°C) -50 / +80
Operating Temp. (°C) -40 / +70

Top